Hydrogen Peroxide Low Temperature Plasma Sterilization Equipment
Hydrogen Peroxide Low Temperature Plasma Sterilization Equipment
Sada Medical Hydrogen Peroxide Low Temperature Plasma Sterilization Equipment
Model: SD-E
Sterilizing Volume: 90L
Application:
Medical Instrument Sterilization Autoclave are widely used in microbiology, medicine, podiatry, tattooing, body piercing, veterinary science, mycology, funeral homes, dentistry, and prosthetics fabrication.
They vary in size and function depending on the media to be sterilized. Typical loads include laboratory glassware, other equipment and waste, surgical instruments and medical waste.
Sterilization Objects: Unwrapped or Wrapped instruments, Sugircal instruments, Glassware, Liquid , Culture Media, Rubber Material, Gowns, Dressing, Gloves, etc.
Shipping Port:Shanghai, Qingdao, Ningbo, Shenzhen, Guangzhou, etc.
Lead Time:20 – 25 working days.
Features of plasma sterilizer
Sterilizing agent: high purity hydrogen peroxide injection (concentration 58%), with inverted hydrogen peroxide automatic
liquid adding system, to ensure that the staff do not directly contact with the liquid;
Sterilization temperature: 50 ℃± 5 ℃
Control: equipment automatic control;
Test method: biological monitoring of Bacillus subtilis and Bacillus stearothermophilus alarm system:
automatic alarm system;
Sterilization room door: electric lift door, equipped with safety system to ensure equipment and personal safety, with anti pinch
designSterilization residue: no toxicity;
Impact on Environment: no impact on safety
Impact on medical staff: the ultraviolet generated by plasma is completely shielded, completely isolated from the operator and
invisible to the naked eye.
Specifications
Brand: Sada Medical
Model: SD-E
Sterilizing Volume: 90L
order number | name | Description of technical parameters |
1 | Model and weight | SD-E 90L |
About 275 KG (net weight) | ||
2 | Cavity structure and material | The cavity structure is rectangular, the cavity material is made of 304 stainless steel, 3mm thickness, square structure, longer service life. The glow electric ion grid is aluminum alloy 5052 with a thickness of 3mm. |
3 | Inner material | hexahedral PTC silicone plate is heated, fully independent temperature control, good thermal conductivity, uniform temperature, the inner tank is equipped with sterilization temperature double protection, effectively guarantee the sterilization effect and the safety of equipment and personnel. |
4 | The sterilization room door | Vertical automatic drive lifting door is adopted, and the door is equipped with anti-clamp hand design safety system to ensure the personal safety of equipment and medical personnel. |
The new cassette plasma has a foot-sensing open and close the door function | ||
5 | sterilizing agent | A cassette packed in 58% hydrogen peroxide had 12 capsules each with a volume of 5ml. |
6 | The method of sterilization | Hydrogen peroxide plasma technology: Hydrogen peroxide online purification technology purithe concentration of hydrogen peroxide to more than 93%, with no residual hydrogen peroxide and no impact on the environment. |
7 | The sterilization speed | Rapid sterilization time 25min; standard sterilization time 35min and enhanced sterilization time 55min |
8 | The sterilization temperature | 50℃±5℃ |
9 | screen size | 7 inch high resolution color touch screen |
master controller PLC | New program design, display working process parameters, convenient to operate, easy to understand, fully realize the control accuracy, standardization, safety, reliability; | |
10 | microwriter | Print multiple records, record sterilization parameters, physical curve of sterilization process, record clearly, long service life |
The sterilization records are kept | Computer printing provides sterilization time, cycle mode, display pressure, sterilization process, merger and sterilization physical graph printing function. The original data can be saved by large capacity storage, with a complete sterilization record of no less than 8000 times, permanent equipment alarm record, printed record can be saved for more than five years, with the function of power off memory. | |
11 | pressure transmitter | Good accuracy, high reliability, and stable output |
12 | temperature senso | Dachang brand, good stability, small measurement error |
13 | sterilizing filter | Ultrafine aseptic filtration, filtration level ≤0.22um |
14 | RF power source | Frequency 19 KHz, maximum power 500W |
15 | electromagnetic valve | High corrosion resistant material, reliable action life |
16 | Chamber temperature heating power | 1800w, no preheat is required |
17 | vacuum pump | The rotary plate vacuum pump with extremely high vacuum degree and H202 corrosion resistance is adopted, and the evacuation rate reaches 16 cubic meters / hour, and the operating sound is less than 65dB |
18 | Vacuum pump phase sequence protector | A high vacuum phase sequence protector is provided to prevent the change, resulting in the reversal of vacuum pump and causing equipment failure |
19 | Oil mist filter | The product has an exhaust oil mist filtration system, which can recover the oil mist, avoid the oil mist into the air, and through the pump suction, the pump oil back to the pump reuse to reduce fuel consumption. |
20 | alarm system | System automatic detection function, real-time monitoring of the sterilization process, if any abnormal, the system automatic alarm, and display the cause of failure in Chinese; |
21 | electro-heating standing-temperature cultivator | Temperature: 56℃ Culture time: 48 hours |
test method | Biometritoring of Fatobacillus thermophila | |
22 | The generation of the plasma species | Single AC discharge mode, to ensure 100% plasma discharge success |
23 | The sterilization residue | Non-toxic damage, no residue |
24 | Impact on the environment | Safety has no impact |
25 | Impact on the medical staff | The ultraviolet light caused by the plasma is completely shielded, completely isolated from the operator, and is invisible to the naked eye. |
26 | Safety of the sterilant | Hydrogen peroxide is ionizes by radiofrequency glow to produce water and oxygen with no residue. |
27 | The consumables are fully equipped | Plasma special indicator card, adhesive tape, packaging bag, sterilizer, biological indicator, biological incubator, etc. shall be uniformly supplied by the manufacturer. |
28 | Cavity size (allowable deviation ± 1%) | 610*480*380mm; |
29 | Outer box size (allowable deviation ± 5%) | 760*790*1600mm; |
30 | Nail box size(allowable deviation ± 5%) | 780*810*1700mm |
31 | Power supply and power | 380v |
2.8KVA | ||
32 | scope of application | Suitable for resistant to vacuum negative pressure and hydrogen peroxide gas and high temperature sensitive devices, not suitable for powder, oil and cotton devices. |
33 | The sterilization effect | 2m Teflon chamber with lmm inner diameter and lmm stainless steel chamber with 500mm. Meet the sterility requirements after sterilization. |