Horizontal Pressure Steam Sterilizer for Laboratory Equipment Online Sale

Horizontal Pressure Steam Sterilizer for Laboratory Equipment

Sada Horizontal Pressure Steam Sterilizer for Laboratory Equipment Online Sale

Model: HA-BW
Sterilizing Volume: 80L, 100L, 120L, 150L, 200L, 300L, 400L

Application:

Medical Instrument Sterilization Autoclave are widely used in microbiology, medicine, podiatry, tattooing, body piercing, veterinary science, mycology, funeral homes, dentistry, and prosthetics fabrication.

They vary in size and function depending on the media to be sterilized. Typical loads include laboratory glassware, other equipment and waste, surgical instruments and medical waste.

Sterilization Objects: Unwrapped or Wrapped instruments, Sugircal instruments, Glassware, Liquid , Culture Media, Rubber Material, Gowns, Dressing, Gloves, etc.

Shipping Port:Shanghai, Qingdao, Ningbo, Shenzhen, Guangzhou, etc.
Lead Time:20 – 25 working days.

Features of Horizontal Pressure Steam Sterilizer

  • Horizontal circular inner chamber + jacket structure, safety, heat preservation, and drying function;
  • Disc type embedded gear + Electric lock door structure,safety and reliable;
  • Door seals are pneumatic or self-expanding
  • Equipped with standard equipment verification interface
  • Pipeline system for the optimal design, SUS304 pipeline, clamp structure, quick assembly
  • Control system: HMI man-machine interface, touch screen + microcomputer;
  • FO value and temperature time double guarantee sterilization effect, with perfect sterilization records;
  • With program selection, parameter setting, equipment operation, report processing and traceability Functions;
  • Multiple safety protection(over-temperature, over-pressure protect)
  • Sterilization process: fabric, equipment, liquid, BD, pressure testing, custom defined multiple procedures

Specifications

Brand: Sada Medical

Model: HA-BW
Sterilizing Volume: 80L, 100L, 120L, 150L, 200L, 300L, 400L

Model&Parameter(Without Pulse Vacuum)

Model Overall

Dimensions

(L×W×H)mm

Chamber Size

(Ø×L)mm

Steam Consumption (KG) Water

Consumption

(KG)

Power(KW) Net Weigh

(KG)

HA-BWS150,HA-BWD150 1290×690×1680 Ø472×880 ≤12 ≤30 ≤2+⑮ 400/450
HA-BWS200,HA-BWD200 1560×690×1680 Ø472×1150 ≤13 ≤190 ≤2+⑮ 450/500
HA-BWS300,HA-BWD300 1430×850×1760 Ø620×995 ≤18 ≤200 ≤2+⑱ 510/570
HA-BWS400,HA-BWD400 1755×850×1760 Ø620×1320 ≤22 ≤200 ≤2+⑱ 650/710

Model&Parameter(With Pulse Vacuum)

Model Overall

Dimensions

(L×W×H)mm

Chamber Size

(Ø×L)mm

Steam Consumption (KG) Water

Consumption

(KG)

Power(KW) Net Weigh Single/Double door

(KG)

HA-100BWV(D) 1160×650×1680 Ø420×750 ≤11 ≤190 ≤2+⑫ 410
HA-150BWV(S),HA-150BWV(D) 1290×690×1680 Ø472×880 ≤13 ≤190 ≤2+⑮ 450/500
HA-200BWV(S),HA-200BWV(D) 1560×690×1680 Ø472×1150 ≤15 ≤190 ≤2+⑮ 500/550
HA-300BWV(S),HA-300BWV(D) 1430×850×1760 Ø620×995 ≤20 ≤200 ≤2+⑱ 560/620
HA-400BWV(S),HA-400BWV(D) 1755×850×1760 Ø620×1320 ≤25 ≤200 ≤2+⑱ 700/760

Note:

1.For example≤2+⑱,the first 2 is the power of the system, and the 18 is the power of the built-in steam generator.But the steam generator is optional.

2.Model “S”means single door,“D”means double,“M” means pulsation vacuum.