100L 150L 200L 300L Horizontal Autoclave With Bowie Dick Test HA-BAV

100L 150L 200L 300L Horizontal Autoclave With Bowie Dick Test HA-BAV

Horizontal Autoclave With Bowie Dick Test HA-BAV

Model: HA-BA
Sterilizing Volume: 150L, 200L, 280L

Application:

Medical Instrument Sterilization Autoclave are widely used in microbiology, medicine, podiatry, tattooing, body piercing, veterinary science, mycology, funeral homes, dentistry, and prosthetics fabrication.

They vary in size and function depending on the media to be sterilized. Typical loads include laboratory glassware, other equipment and waste, surgical instruments and medical waste.

Sterilization Objects: Unwrapped or Wrapped instruments, Sugircal instruments, Glassware, Liquid , Culture Media, Rubber Material, Gowns, Dressing, Gloves, etc.

Shipping Port:Shanghai, Qingdao, Ningbo, Shenzhen, Guangzhou, etc.
Lead Time:20 – 25 working days.

Features of Horizontal Pressure Steam Sterilizer

Touch screen, micro-computer automatically control the sterilizing process, no need supervision, easy to operate.
It has 3 times or more pulsating vacuum. Suitable for all kinds of packed, non packed, hollow porous and internal pipeline
instruments.
The sterilizer is equipped with a built-in steam generator, and one set of movable sterilization plate is randomly adapted.
The inner chamber is a circular double-layer design, which is composed of a sterilization chamber and a jacket, and has the
function of deep drying.
With printing function, the printer can record the whole process of sterilization.
With Bowie & Dick test function for steam penetration test.
With 7-in color touch screen, easy to operate and can display time, pressure, temperature etc.
With more than 6 types sterilization programs, the user can choose the program according to the objects will be sterilized.
With over-temperature, over-pressure auto-protect.
Safety interlock device: when the door is not closed tightly, steam can not enter the main body of the inner layer and give an
alarm. When the pressure in the sterilization room is greater than 0.027mpa, the door is interlocked and cannot be opened.
Over-pressure protection: when the pressure exceeds the working pressure, the safety valve will automatically relieve the
pressure.
Low water level protection device: the water can not be started until the high water level, and it will be automatically cut
off when the low water level is short of water.
Over current protection: when the current overload, the power circuit breaker will automatically cut off the power supply.
Sealing door: manual door opening and closing, radial rod rotary table type, equipped with two-stage self-locking, interlocking
safety device, single door (double door optional), with pressure safety interlock device.
The sterilization room is made of high quality stainless steel.
Single door or double door can be made (Optional).

Specifications

Brand: Sada Medical

Model: HA-BAV
Sterilizing Volume: 100L, 150L, 200L,300L

MODEL

HA-BAV100

HA-BAV150 HA-BAV200

HA-BAV300

Chamber volume 100L

Φ440x670mm

150L

Φ440x1000mm

200L

Φ515x100mm

300L

Φ600x1080mm

Max working pressure

0.22Mpa

Max working temp.

134℃

Temp. selection

115-134℃

Sterilization Time

0-99 min

Drying time

0-99 min

Heat average

≤±2℃

Vacuum limit

-0.08Mpa

Power/ Supply Voltage

10KW/380V, 50HZ

10KW/380V, 50HZ 10KW/380V, 50HZ 13KW/380V, 50HZ
Overall size 1400x660x1640 1400x660x1640 1400x750x1740 1520x850x1850
Package size 1560x820x1820 1560x820x1820 1560x910x1880 1680x1080x2100
G. W/N.W 430/340KG 440/350KG 460/370KG 580/470KG

Delivered Orders